Filter Results By:

Products

Applications

Manufacturers

Partial Discharge

voltage discharge within an insulator causing dielectric breakdown.

See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test


Showing results: 106 - 120 of 128 items found.

  • Insulation Resistance Meter

    AMIC-15k1 - Amperis sl

    *The partial discharge indicator PDI.*Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD*Allows to test the electrical durability of the tested object - indication of breaking voltage.*The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.

  • Electrical Safety Multi-Analyzer

    TOS9300 Series - Kikusui Electronics Corp.

    The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • High Frequency Current Transformer

    HFCT - IPEC Ltd.

    The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.

  • Cable Diagnostic Tools

    High Voltage Inc.

    For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.

  • Compact Ultrasonic Testing Device

    SONAPHONE® Pocket - SONOTEC GmbH

    With the SONAPHONE Pocket you identify problems even before they arise and create value at all levels of your company. Just by detecting and eliminating leaks you can reduce the energy costs for your compressed air system up to 30 percent. This also has positive effects on your operational safety and system productivity through early warning of bearing failure and evidence of partial electrical discharges.

  • Qualification and Quality Control Tests

    Techsquare - Techimp HQ S.r.L

    New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.

  • UHF PD Detector

    Megger Group Ltd.

    Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.

  • Horn Antenna

    Techimp HQ S.r.L

    Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.

  • Test & Automation

    Power Diagnostix Systems GmbH

    Partial discharge testing – well established for high voltage equipment – becomes increasingly important for insulation systems of a lower voltage level. Changing to switching power supply and to IGBT control of induction motors, for instance, raise demands and testing needs for the insulation system. The modular concept of Power Diagnostix’ instruments allows offering customized solutions for automated and semi-automated testing.

  • Electrical Safety Testers

    Kikusui Electronics Corp.

    a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • Flexible Magnetic Coupler

    FMC - Techimp HQ S.r.L

    The FMC (Flexible Magnetic Coupler) is a partial discharge sensor whose working principle is based on a direct magnetic coupling with the cable conductor and shield.It picks up a magnetic signal given by PD activity. His compact and robust design makes the FMC the optimal sensor for direct installation on cables and accessories such as joints and termination.This sensor has a sensitive side which has to face to the object under test, while the other side (shielded) reject the noise from the environment.

  • Dielectric Loss Tangent Testing Instruments

    Soken Electric Co. Ltd

    Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.

  • AC Insulation Testing

    Weshine Electric Manufacturing Co., Ltd

    High-voltage Dividers (High Potential Divider) are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they are used to measure alternating voltage (AC), direct voltage (DC), lightning impulse voltage (LI), and switching impulse voltage (SI) systems. High-voltage dividers by HIGHVOLT comply with the relevant IEC standards. The systems are available for both indoor and outdoor use.

  • Universal PD & EMI analyzer

    Spark P3 - Manta Test Systems

    Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.

  • Battery Cell Insulation Tester

    Chroma 11210 - Chroma Systems Solutions, Inc.

    Chroma 11210 battery cell insulation tester is an instrument used for accurately measuring leakage current (LC) and insulation resistance(IR) of battery jelly-roll/dry-cell as well as other insulation materials. In addition to standard LC/IR measurement, the 11210 has a unique function that detects partial discharge (PD) or flashover that may have occurred inside the insulation material during the high voltage insulation testing process.

Get Help